Sinexcel Active Harmonic Filters (AHF)

Real-time harmonic mitigation for THDi ≤ 5%. Comply with IEEE 519 and protect sensitive industrial equipment.

Get Expert Quote
Sinexcel Active Harmonic Filter

PS Power Controls is a leading distributor of Sinexcel Active Harmonic Filters (AHF) in Chennai and across India. In modern power systems, non-linear loads like VFDs, UPS, and SMPS generate significant harmonics, leading to overheating, energy losses, and equipment failure. Our AHF solutions dynamically monitor and cancel these harmonics in real-time, ensuring your facility remains compliant with international standards like IEEE 519.

Advanced Technology

Real-Time Response

Fastest response time (< 5ms) to dynamic load changes, ensuring continuous protection.

3-Level Topology

Delivers higher efficiency, lower thermal loss, and a cleaner sinusoidal waveform.

Modular Design

Compact, wall-mounted or rack-mounted modules for easy scalability and maintenance.

Multi-Functional

Simultaneously compensates for harmonics, reactive power (PF), and phase imbalance.

Technical Specifications

Sinexcel AHF units are built for the most demanding power quality environments:

Harmonic Compensation 2nd to 50th order (Individual order selectable)
THDi Achievement ≤ 5% (Typically after compensation)
Response Time Full Response < 5ms / Instant Response < 100μs
Topology 3-Level NPC Topology (High Efficiency)
Cooling Independent air duct cooling system
Communication RS485 / Modbus / Ethernet / HMI Touch Screen
Certification CE, TUV, IEEE 519 compliant

Industry Applications

Our Active Harmonic Filters are essential for:

  • Data Centers: Protecting sensitive servers and IT infrastructure from power distortion.
  • Automotive & Manufacturing: Ensuring precision in robotic and CNC operations.
  • Water Treatment: Optimizing VFD performance in pumping stations.
  • Commercial Buildings: Managing harmonics from LED lighting and large HVAC systems.
  • Hospitals: Protecting critical medical imaging and life-support equipment.

Frequently Asked Questions

Why is Sinexcel the preferred choice for AHF in India?
Sinexcel is a global leader in power quality. Their AHFs are known for their compact modular design, exceptional 3-level topology efficiency, and reliable performance in harsh industrial conditions. PS Power Controls provides local expert installation and support in Chennai.
What is the difference between AHF and SVG?
While both use power electronics, an Active Harmonic Filter (AHF) primarily focuses on cleaning up harmonic distortion. A Static Var Generator (SVG) is optimized for high-speed reactive power compensation (Power Factor improvement). Sinexcel's ASVG models combine both functions.
How do I determine the AHF capacity I need?
Capacity is determined through a site harmonic audit. We measure your current THDi levels and load profile to calculate the required Amperes of compensation needed to reach your target THDi (e.g., < 5%).

Stop Harmonic Pollution Today

Contact PS Power Controls for a professional site survey and harmonic mitigation proposal.

Copyrights © 2026 All Rights Reserved www.pspowercontrols.com

Related Solutions

Explore complementary power quality solutions to improve efficiency, reduce penalties, and improve equipment reliability.

APFC Panel | Active Harmonic Filter | Passive Harmonic Filter | Energy Audit Services | Get Technical Consultation

Chennai Deployment Notes

PS Power Controls supports end-to-end implementation across Chennai and Tamil Nadu, including load assessment, solution sizing, panel integration, and commissioning guidance. Our engineering recommendations are based on real operating conditions, utility penalty behavior, and site reliability priorities.

For project planning, combine this solution with energy audits, harmonic analysis, and consultation from our technical team. This approach improves power quality outcomes while reducing rework risk during deployment.